0. Device
2. Device.definition
Control0..0
4. Device.udiCarrier
Control0..0
6. Device.statusReason
Control0..0
8. Device.distinctIdentifier
Control0..0
10. Device.manufactureDate
Control0..0
12. Device.expirationDate
Control0..0
14. Device.lotNumber
Control0..0
16. Device.deviceName
Control0..0
18. Device.modelNumber
Control0..0
20. Device.partNumber
Control0..0
22. Device.specialization
Control0..0
24. Device.version
NoteThis is a business versionId, not a resource version id (see discussion)
Control0..0
26. Device.property
Control0..0
28. Device.patient
Control0..0
30. Device.contact
Control0..0
32. Device.location
Control0..0
34. Device.url
Control0..0
36. Device.note
Control0..0
38. Device.safety
Control0..0
40. Device.parent
Control0..0

Guidance on how to interpret the contents of this table can be found here

0. Device
Definition

A type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.

ShortItem used in healthcare
Control0..*
Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
2. Device.meta
Definition

The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

ShortMetadata about the resource
Control0..1
This element is affected by the following invariants: ele-1
TypeMeta
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. Device.meta.extension:as-ext-data-trace
Slice Nameas-ext-data-trace
Definition

Extension créée dans le cadre de l'Annuaire Santé pour tracer l'origine de la donnée (Autorité d'Enregistrement (AE) et Système d'Information (SI)). Des études complémentaires vont être initiées pour envisager l'usage de la ressource Provenance ou meta.source

ShortDataTrace : Informe sur l'origine de la donnée (Autorité d'Enregistrement (AE) et Système d'Information (SI).
Control0..1
This element is affected by the following invariants: ele-1
TypeExtension(AS Data Trace Extension) (Complex Extension)
Must Supporttrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
6. Device.implicitRules
Definition

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

ShortA set of rules under which this content was created
Comments

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

Control0..1
This element is affected by the following invariants: ele-1
Typeuri
Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
8. Device.extension:as-ext-healthcareservice-authorization
Slice Nameas-ext-healthcareservice-authorization
Definition

Extension créée dans le cadre de l'Annuaire Santé pour décrire les autorisations des activités sanitaires, sociales, médico-sociales et d'enseignement et des équipements matériels lourds autorisés.

ShortAS HealthcareService Autorization Extension
Control0..1
This element is affected by the following invariants: ele-1
TypeExtension(AS HealthcareService Autorization Extension) (Complex Extension)
Must Supporttrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
10. Device.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
This element is affected by the following invariants: ele-1
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Standards StatusNormative (from Trial Use)
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
SlicingThis element introduces a set of slices on Device.modifierExtension. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • value @ url
  • 12. Device.identifier
    Definition

    Unique instance identifiers assigned to a device by manufacturers other organizations or owners.

    ShortInstance identifier
    Comments

    The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.

    NoteThis is a business identifier, not a resource identifier (see discussion)
    Control0..*
    This element is affected by the following invariants: ele-1
    TypeIdentifier
    Must Supporttrue
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    SlicingThis element introduces a set of slices on Device.identifier. The slices are unordered and Open, and can be differentiated using the following discriminators:
    • pattern @ system
    • 14. Device.identifier:numAutorisationArhgos
      Slice NamenumAutorisationArhgos
      Definition

      Unique instance identifiers assigned to a device by manufacturers other organizations or owners.

      ShortIdentifiant fonctionnel, numéro d'autorisation ARHGOS (numeroAutorisationARHGOS). Le system est mis à titre indicatif et pourra évoluer.Instance identifier
      Comments

      The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.

      NoteThis is a business identifier, not a resource identifier (see discussion)
      Control0..1*
      This element is affected by the following invariants: ele-1
      TypeIdentifier
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      16. Device.identifier:numAutorisationArhgos.use
      Definition

      The purpose of this identifier.

      Shortusual | official | temp | secondary | old (If known)
      Comments

      Applications can assume that an identifier is permanent unless it explicitly says that it is temporary.

      Control0..1
      This element is affected by the following invariants: ele-1
      BindingThe codes SHALL be taken from IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1
      (required to http://hl7.org/fhir/ValueSet/identifier-use|4.0.1)

      Identifies the purpose for this identifier, if known .

      Typecode
      Is Modifiertrue because This is labeled as "Is Modifier" because applications should not mistake a temporary id for a permanent one.
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Requirements

      Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      18. Device.identifier:numAutorisationArhgos.system
      Definition

      Establishes the namespace for the value - that is, a URL that describes a set values that are unique.

      ShortThe namespace for the identifier value
      Comments

      Identifier.system is always case sensitive.

      Control10..1
      This element is affected by the following invariants: ele-1
      Typeuri
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Requirements

      There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers.

      Pattern Valuehttps://arhgos.ars.sante.fr
      Example<br/><b>General</b>:http://www.acme.com/identifiers/patient
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      20. Device.definition
      Definition

      The reference to the definition for the device.

      ShortThe reference to the definition for the device
      Comments

      References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

      Control0..01
      This element is affected by the following invariants: ele-1
      TypeReference(DeviceDefinition)
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
      22. Device.udiCarrier
      Definition

      Unique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold.

      ShortUnique Device Identifier (UDI) Barcode string
      Comments

      UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device.

      Control0..0*
      This element is affected by the following invariants: ele-1
      TypeBackboneElement
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      25. Device.status
      Definition

      Status of the Device availability.

      ShortLe matériel est-il actif? active | inactiveactive | inactive | entered-in-error | unknown
      Comments

      This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid.

      Control0..1
      This element is affected by the following invariants: ele-1
      BindingThe codes SHALL be taken from FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1
      (required to http://hl7.org/fhir/ValueSet/device-status|4.0.1)

      The availability status of the device.

      Typecode
      Is Modifiertrue because This element is labelled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      27. Device.statusReason
      Definition

      Reason for the dtatus of the Device availability.

      Shortonline | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
      Comments

      Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

      Control0..0*
      This element is affected by the following invariants: ele-1
      BindingUnless not suitable, these codes SHALL be taken from FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason
      (extensible to http://hl7.org/fhir/ValueSet/device-status-reason)

      The availability status reason of the device.

      TypeCodeableConcept
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      29. Device.distinctIdentifier
      Definition

      The distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product.

      ShortThe distinct identification string
      Comments

      For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c).

      Control0..01
      This element is affected by the following invariants: ele-1
      Typestring
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Alternate NamesDistinct Identification Code (DIC)
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      31. Device.manufacturer
      Definition

      A name of the manufacturer.

      ShortMarque de l'équipement matériel lourd.Name of device manufacturer
      Comments

      Note that FHIR strings SHALL NOT exceed 1MB in size

      Control0..1
      This element is affected by the following invariants: ele-1
      Typestring
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      33. Device.manufactureDate
      Definition

      The date and time when the device was manufactured.

      ShortDate when the device was made
      Control0..01
      This element is affected by the following invariants: ele-1
      TypedateTime
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      35. Device.expirationDate
      Definition

      The date and time beyond which this device is no longer valid or should not be used (if applicable).

      ShortDate and time of expiry of this device (if applicable)
      Control0..01
      This element is affected by the following invariants: ele-1
      TypedateTime
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      37. Device.lotNumber
      Definition

      Lot number assigned by the manufacturer.

      ShortLot number of manufacture
      Comments

      Note that FHIR strings SHALL NOT exceed 1MB in size

      Control0..01
      This element is affected by the following invariants: ele-1
      Typestring
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      39. Device.serialNumber
      Definition

      The serial number assigned by the organization when the device was manufactured.

      ShortNuméro de série de l'équipement matériel lourd (numeroSerie).Serial number assigned by the manufacturer
      Comments

      Alphanumeric Maximum 20.

      Control0..1
      This element is affected by the following invariants: ele-1
      Typestring
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      41. Device.deviceName
      Definition

      This represents the manufacturer's name of the device as provided by the device, from a UDI label, or by a person describing the Device. This typically would be used when a person provides the name(s) or when the device represents one of the names available from DeviceDefinition.

      ShortThe name of the device as given by the manufacturer
      Control0..0*
      This element is affected by the following invariants: ele-1
      TypeBackboneElement
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      46. Device.modelNumber
      Definition

      The model number for the device.

      ShortThe model number for the device
      Comments

      Note that FHIR strings SHALL NOT exceed 1MB in size

      Control0..01
      This element is affected by the following invariants: ele-1
      Typestring
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      48. Device.partNumber
      Definition

      The part number of the device.

      ShortThe part number of the device
      Comments

      Alphanumeric Maximum 20.

      Control0..01
      This element is affected by the following invariants: ele-1
      Typestring
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      50. Device.type
      Definition

      The kind or type of device.

      ShortCode définissant l'équipement matériel lourd (EML) soumis à autorisation.The kind or type of device
      Comments

      Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

      Control0..1
      This element is affected by the following invariants: ele-1
      BindingThe codes SHALL be taken from For example codes, see JDV_J135-EquipementMaterielLourd-RASShttp://hl7.org/fhir/ValueSet/device-type
      (required to https://mos.esante.gouv.fr/NOS/JDV_J135-EquipementMaterielLourd-RASS/FHIR/JDV-J135-EquipementMaterielLourd-RASS)
      TypeCodeableConcept
      Must Supporttrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      52. Device.specialization
      Definition

      The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication.

      ShortThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
      Control0..0*
      This element is affected by the following invariants: ele-1
      TypeBackboneElement
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      56. Device.version
      Definition

      The actual design of the device or software version running on the device.

      ShortThe actual design of the device or software version running on the device
      NoteThis is a business versionId, not a resource version id (see discussion)
      Control0..0*
      This element is affected by the following invariants: ele-1
      TypeBackboneElement
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      60. Device.property
      Definition

      The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties.

      ShortThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
      Control0..0*
      This element is affected by the following invariants: ele-1
      TypeBackboneElement
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      64. Device.patient
      Definition

      Patient information, If the device is affixed to a person.

      ShortPatient to whom Device is affixed
      Comments

      References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

      Control0..01
      This element is affected by the following invariants: ele-1
      TypeReference(Patient)
      Requirements

      If the device is implanted in a patient, then need to associate the device to the patient.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
      66. Device.owner
      Definition

      An organization that is responsible for the provision and ongoing maintenance of the device.

      ShortRéférence vers l'id de la structure FINESS ET à laquelle est rattaché cet équipement matériel lourd (idStructure).Organization responsible for device
      Comments

      References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

      Control0..1
      This element is affected by the following invariants: ele-1
      TypeReference(FR Core Organization Profile, AS Organization Profile, Organization)
      Must Supporttrue
      Must Support TypesNo must-support rules about the choice of types/profiles
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
      68. Device.contact
      Definition

      Contact details for an organization or a particular human that is responsible for the device.

      ShortDetails for human/organization for support
      Comments

      used for troubleshooting etc.

      Control0..0*
      This element is affected by the following invariants: ele-1
      TypeContactPoint
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      cpt-2: A system is required if a value is provided. (value.empty() or system.exists())
      70. Device.location
      Definition

      The place where the device can be found.

      ShortWhere the device is found
      Comments

      References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

      Control0..01
      This element is affected by the following invariants: ele-1
      TypeReference(Location)
      Requirements

      Device.location can be used to track device location.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
      72. Device.url
      Definition

      A network address on which the device may be contacted directly.

      ShortNetwork address to contact device
      Comments

      If the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved.

      Control0..01
      This element is affected by the following invariants: ele-1
      Typeuri
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      74. Device.note
      Definition

      Descriptive information, usage information or implantation information that is not captured in an existing element.

      ShortDevice notes and comments
      Comments

      For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible).

      Control0..0*
      This element is affected by the following invariants: ele-1
      TypeAnnotation
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      76. Device.safety
      Definition

      Provides additional safety characteristics about a medical device. For example devices containing latex.

      ShortSafety Characteristics of Device
      Comments

      Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

      Control0..0*
      This element is affected by the following invariants: ele-1
      TypeCodeableConcept
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      78. Device.parent
      Definition

      The parent device.

      ShortThe parent device
      Comments

      References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

      Control0..01
      This element is affected by the following invariants: ele-1
      TypeReference(Device)
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))

      Guidance on how to interpret the contents of this table can be found here

      0. Device
      Definition

      A type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.

      ShortItem used in healthcare
      Control0..*
      Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
      dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
      dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
      dom-6: A resource should have narrative for robust management (text.`div`.exists())
      dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
      2. Device.id
      Definition

      The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes.

      ShortLogical id of this artifact
      Comments

      The only time that a resource does not have an id is when it is being submitted to the server using a create operation.

      Control0..1
      Typeid
      Summarytrue
      4. Device.meta
      Definition

      The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

      ShortMetadata about the resource
      Control0..1
      This element is affected by the following invariants: ele-1
      TypeMeta
      Summarytrue
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      6. Device.meta.id
      Definition

      Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

      ShortUnique id for inter-element referencing
      Control0..1
      Typestring
      XML FormatIn the XML format, this property is represented as an attribute.
      8. Device.meta.extension
      Definition

      May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

      ShortAdditional content defined by implementations
      Comments

      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

      Control0..*
      This element is affected by the following invariants: ele-1
      TypeExtension
      Standards StatusNormative (from Trial Use)
      Alternate Namesextensions, user content
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      SlicingThis element introduces a set of slices on Device.meta.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
      • value @ url
      • 10. Device.meta.extension:as-ext-data-trace
        Slice Nameas-ext-data-trace
        Definition

        Extension créée dans le cadre de l'Annuaire Santé pour tracer l'origine de la donnée (Autorité d'Enregistrement (AE) et Système d'Information (SI)). Des études complémentaires vont être initiées pour envisager l'usage de la ressource Provenance ou meta.source

        ShortDataTrace : Informe sur l'origine de la donnée (Autorité d'Enregistrement (AE) et Système d'Information (SI).
        Control0..1
        This element is affected by the following invariants: ele-1
        TypeExtension(AS Data Trace Extension) (Complex Extension)
        Must Supporttrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        12. Device.meta.versionId
        Definition

        The version specific identifier, as it appears in the version portion of the URL. This value changes when the resource is created, updated, or deleted.

        ShortVersion specific identifier
        Comments

        The server assigns this value, and ignores what the client specifies, except in the case that the server is imposing version integrity on updates/deletes.

        Control0..1
        This element is affected by the following invariants: ele-1
        Typeid
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        14. Device.meta.lastUpdated
        Definition

        When the resource last changed - e.g. when the version changed.

        ShortWhen the resource version last changed
        Comments

        This value is always populated except when the resource is first being created. The server / resource manager sets this value; what a client provides is irrelevant. This is equivalent to the HTTP Last-Modified and SHOULD have the same value on a read interaction.

        Control0..1
        This element is affected by the following invariants: ele-1
        Typeinstant
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        16. Device.meta.source
        Definition

        A uri that identifies the source system of the resource. This provides a minimal amount of Provenance information that can be used to track or differentiate the source of information in the resource. The source may identify another FHIR server, document, message, database, etc.

        ShortIdentifies where the resource comes from
        Comments

        In the provenance resource, this corresponds to Provenance.entity.what[x]. The exact use of the source (and the implied Provenance.entity.role) is left to implementer discretion. Only one nominated source is allowed; for additional provenance details, a full Provenance resource should be used.

        This element can be used to indicate where the current master source of a resource that has a canonical URL if the resource is no longer hosted at the canonical URL.

        Control0..1
        This element is affected by the following invariants: ele-1
        Typeuri
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        18. Device.meta.profile
        Definition

        A list of profiles (references to StructureDefinition resources) that this resource claims to conform to. The URL is a reference to StructureDefinition.url.

        ShortProfiles this resource claims to conform to
        Comments

        It is up to the server and/or other infrastructure of policy to determine whether/how these claims are verified and/or updated over time. The list of profile URLs is a set.

        Control0..*
        This element is affected by the following invariants: ele-1
        Typecanonical(StructureDefinition)
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        20. Device.meta.security
        Definition

        Security labels applied to this resource. These tags connect specific resources to the overall security policy and infrastructure.

        ShortSecurity Labels applied to this resource
        Comments

        The security labels can be updated without changing the stated version of the resource. The list of security labels is a set. Uniqueness is based the system/code, and version and display are ignored.

        Control0..*
        This element is affected by the following invariants: ele-1
        BindingUnless not suitable, these codes SHALL be taken from All Security Labels
        (extensible to http://hl7.org/fhir/ValueSet/security-labels)

        Security Labels from the Healthcare Privacy and Security Classification System.

        TypeCoding
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        22. Device.meta.tag
        Definition

        Tags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource.

        ShortTags applied to this resource
        Comments

        The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored.

        Control0..*
        This element is affected by the following invariants: ele-1
        BindingFor example codes, see CommonTags
        (example to http://hl7.org/fhir/ValueSet/common-tags)

        Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones".

        TypeCoding
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        24. Device.implicitRules
        Definition

        A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

        ShortA set of rules under which this content was created
        Comments

        Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

        Control0..1
        This element is affected by the following invariants: ele-1
        Typeuri
        Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        26. Device.language
        Definition

        The base language in which the resource is written.

        ShortLanguage of the resource content
        Comments

        Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).

        Control0..1
        This element is affected by the following invariants: ele-1
        BindingThe codes SHOULD be taken from CommonLanguages
        (preferred to http://hl7.org/fhir/ValueSet/languages)

        A human language.

        Additional BindingsPurpose
        AllLanguagesMax Binding
        Typecode
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        28. Device.text
        Definition

        A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety.

        ShortText summary of the resource, for human interpretation
        Comments

        Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.

        Control0..1
        This element is affected by the following invariants: ele-1
        TypeNarrative
        Alternate Namesnarrative, html, xhtml, display
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        30. Device.contained
        Definition

        These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope.

        ShortContained, inline Resources
        Comments

        This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.

        Control0..*
        TypeResource
        Alternate Namesinline resources, anonymous resources, contained resources
        32. Device.extension
        Definition

        May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

        ShortAdditional content defined by implementations
        Comments

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Control0..*
        This element is affected by the following invariants: ele-1
        TypeExtension
        Standards StatusNormative (from Trial Use)
        Alternate Namesextensions, user content
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        SlicingThis element introduces a set of slices on Device.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
        • value @ url
        • 34. Device.extension:as-ext-healthcareservice-authorization
          Slice Nameas-ext-healthcareservice-authorization
          Definition

          Extension créée dans le cadre de l'Annuaire Santé pour décrire les autorisations des activités sanitaires, sociales, médico-sociales et d'enseignement et des équipements matériels lourds autorisés.

          ShortAS HealthcareService Autorization Extension
          Control0..1
          This element is affected by the following invariants: ele-1
          TypeExtension(AS HealthcareService Autorization Extension) (Complex Extension)
          Must Supporttrue
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          36. Device.modifierExtension
          Definition

          May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

          Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

          ShortExtensions that cannot be ignored
          Comments

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Control0..*
          This element is affected by the following invariants: ele-1
          TypeExtension
          Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
          Standards StatusNormative (from Trial Use)
          Requirements

          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

          Alternate Namesextensions, user content
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          SlicingThis element introduces a set of slices on Device.modifierExtension. The slices are unordered and Open, and can be differentiated using the following discriminators:
          • value @ url
          • 38. Device.identifier
            Definition

            Unique instance identifiers assigned to a device by manufacturers other organizations or owners.

            ShortInstance identifier
            Comments

            The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.

            NoteThis is a business identifier, not a resource identifier (see discussion)
            Control0..*
            This element is affected by the following invariants: ele-1
            TypeIdentifier
            Must Supporttrue
            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            SlicingThis element introduces a set of slices on Device.identifier. The slices are unordered and Open, and can be differentiated using the following discriminators:
            • pattern @ system
            • 40. Device.identifier:numAutorisationArhgos
              Slice NamenumAutorisationArhgos
              Definition

              Unique instance identifiers assigned to a device by manufacturers other organizations or owners.

              ShortIdentifiant fonctionnel, numéro d'autorisation ARHGOS (numeroAutorisationARHGOS). Le system est mis à titre indicatif et pourra évoluer.
              Comments

              The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.

              NoteThis is a business identifier, not a resource identifier (see discussion)
              Control0..1
              This element is affected by the following invariants: ele-1
              TypeIdentifier
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              42. Device.identifier:numAutorisationArhgos.id
              Definition

              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

              ShortUnique id for inter-element referencing
              Control0..1
              Typestring
              XML FormatIn the XML format, this property is represented as an attribute.
              44. Device.identifier:numAutorisationArhgos.extension
              Definition

              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

              ShortAdditional content defined by implementations
              Comments

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Control0..*
              This element is affected by the following invariants: ele-1
              TypeExtension
              Standards StatusNormative (from Trial Use)
              Alternate Namesextensions, user content
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              SlicingThis element introduces a set of slices on Device.identifier.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
              • value @ url
              • 46. Device.identifier:numAutorisationArhgos.use
                Definition

                The purpose of this identifier.

                Shortusual | official | temp | secondary | old (If known)
                Comments

                Applications can assume that an identifier is permanent unless it explicitly says that it is temporary.

                Control0..1
                This element is affected by the following invariants: ele-1
                BindingThe codes SHALL be taken from IdentifierUse
                (required to http://hl7.org/fhir/ValueSet/identifier-use|4.0.1)

                Identifies the purpose for this identifier, if known .

                Typecode
                Is Modifiertrue because This is labeled as "Is Modifier" because applications should not mistake a temporary id for a permanent one.
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Summarytrue
                Requirements

                Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                48. Device.identifier:numAutorisationArhgos.type
                Definition

                A coded type for the identifier that can be used to determine which identifier to use for a specific purpose.

                ShortDescription of identifier
                Comments

                This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type.

                Control0..1
                This element is affected by the following invariants: ele-1
                BindingUnless not suitable, these codes SHALL be taken from Identifier Type Codes
                (extensible to http://hl7.org/fhir/ValueSet/identifier-type)

                A coded type for an identifier that can be used to determine which identifier to use for a specific purpose.

                TypeCodeableConcept
                Summarytrue
                Requirements

                Allows users to make use of identifiers when the identifier system is not known.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                50. Device.identifier:numAutorisationArhgos.system
                Definition

                Establishes the namespace for the value - that is, a URL that describes a set values that are unique.

                ShortThe namespace for the identifier value
                Comments

                Identifier.system is always case sensitive.

                Control1..1
                This element is affected by the following invariants: ele-1
                Typeuri
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Summarytrue
                Requirements

                There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers.

                Pattern Valuehttps://arhgos.ars.sante.fr
                Example<br/><b>General</b>:http://www.acme.com/identifiers/patient
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                52. Device.identifier:numAutorisationArhgos.value
                Definition

                The portion of the identifier typically relevant to the user and which is unique within the context of the system.

                ShortThe value that is unique
                Comments

                If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.

                Control0..1
                This element is affected by the following invariants: ele-1
                Typestring
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Summarytrue
                Example<br/><b>General</b>:123456
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                54. Device.identifier:numAutorisationArhgos.period
                Definition

                Time period during which identifier is/was valid for use.

                ShortTime period when id is/was valid for use
                Comments

                A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times").

                Period is not used for a duration (a measure of elapsed time). See Duration.

                Control0..1
                This element is affected by the following invariants: ele-1
                TypePeriod
                Summarytrue
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                per-1: If present, start SHALL have a lower value than end (start.hasValue().not() or end.hasValue().not() or (start <= end))
                56. Device.identifier:numAutorisationArhgos.assigner
                Definition

                Organization that issued/manages the identifier.

                ShortOrganization that issued id (may be just text)
                Comments

                The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.

                Control0..1
                This element is affected by the following invariants: ele-1
                TypeReference(Organization)
                Summarytrue
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
                58. Device.definition
                Definition

                The reference to the definition for the device.

                ShortThe reference to the definition for the device
                Comments

                References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

                Control0..0
                This element is affected by the following invariants: ele-1
                TypeReference(DeviceDefinition)
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
                60. Device.udiCarrier
                Definition

                Unique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold.

                ShortUnique Device Identifier (UDI) Barcode string
                Comments

                UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device.

                Control0..0
                This element is affected by the following invariants: ele-1
                TypeBackboneElement
                Summarytrue
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                71. Device.status
                Definition

                Status of the Device availability.

                ShortLe matériel est-il actif? active | inactive
                Comments

                This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid.

                Control0..1
                This element is affected by the following invariants: ele-1
                BindingThe codes SHALL be taken from FHIRDeviceStatus
                (required to http://hl7.org/fhir/ValueSet/device-status|4.0.1)

                The availability status of the device.

                Typecode
                Is Modifiertrue because This element is labelled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Must Supporttrue
                Summarytrue
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                73. Device.statusReason
                Definition

                Reason for the dtatus of the Device availability.

                Shortonline | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
                Comments

                Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

                Control0..0
                This element is affected by the following invariants: ele-1
                BindingUnless not suitable, these codes SHALL be taken from FHIRDeviceStatusReason
                (extensible to http://hl7.org/fhir/ValueSet/device-status-reason)

                The availability status reason of the device.

                TypeCodeableConcept
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                75. Device.distinctIdentifier
                Definition

                The distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product.

                ShortThe distinct identification string
                Comments

                For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c).

                Control0..0
                This element is affected by the following invariants: ele-1
                Typestring
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Alternate NamesDistinct Identification Code (DIC)
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                77. Device.manufacturer
                Definition

                A name of the manufacturer.

                ShortMarque de l'équipement matériel lourd.
                Comments

                Note that FHIR strings SHALL NOT exceed 1MB in size

                Control0..1
                This element is affected by the following invariants: ele-1
                Typestring
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Must Supporttrue
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                79. Device.manufactureDate
                Definition

                The date and time when the device was manufactured.

                ShortDate when the device was made
                Control0..0
                This element is affected by the following invariants: ele-1
                TypedateTime
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                81. Device.expirationDate
                Definition

                The date and time beyond which this device is no longer valid or should not be used (if applicable).

                ShortDate and time of expiry of this device (if applicable)
                Control0..0
                This element is affected by the following invariants: ele-1
                TypedateTime
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                83. Device.lotNumber
                Definition

                Lot number assigned by the manufacturer.

                ShortLot number of manufacture
                Comments

                Note that FHIR strings SHALL NOT exceed 1MB in size

                Control0..0
                This element is affected by the following invariants: ele-1
                Typestring
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                85. Device.serialNumber
                Definition

                The serial number assigned by the organization when the device was manufactured.

                ShortNuméro de série de l'équipement matériel lourd (numeroSerie).
                Comments

                Alphanumeric Maximum 20.

                Control0..1
                This element is affected by the following invariants: ele-1
                Typestring
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Must Supporttrue
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                87. Device.deviceName
                Definition

                This represents the manufacturer's name of the device as provided by the device, from a UDI label, or by a person describing the Device. This typically would be used when a person provides the name(s) or when the device represents one of the names available from DeviceDefinition.

                ShortThe name of the device as given by the manufacturer
                Control0..0
                This element is affected by the following invariants: ele-1
                TypeBackboneElement
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                94. Device.modelNumber
                Definition

                The model number for the device.

                ShortThe model number for the device
                Comments

                Note that FHIR strings SHALL NOT exceed 1MB in size

                Control0..0
                This element is affected by the following invariants: ele-1
                Typestring
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                96. Device.partNumber
                Definition

                The part number of the device.

                ShortThe part number of the device
                Comments

                Alphanumeric Maximum 20.

                Control0..0
                This element is affected by the following invariants: ele-1
                Typestring
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                98. Device.type
                Definition

                The kind or type of device.

                ShortCode définissant l'équipement matériel lourd (EML) soumis à autorisation.
                Comments

                Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

                Control0..1
                This element is affected by the following invariants: ele-1
                BindingThe codes SHALL be taken from JDV_J135-EquipementMaterielLourd-RASS
                (required to https://mos.esante.gouv.fr/NOS/JDV_J135-EquipementMaterielLourd-RASS/FHIR/JDV-J135-EquipementMaterielLourd-RASS)
                TypeCodeableConcept
                Must Supporttrue
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                100. Device.specialization
                Definition

                The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication.

                ShortThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
                Control0..0
                This element is affected by the following invariants: ele-1
                TypeBackboneElement
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                107. Device.version
                Definition

                The actual design of the device or software version running on the device.

                ShortThe actual design of the device or software version running on the device
                NoteThis is a business versionId, not a resource version id (see discussion)
                Control0..0
                This element is affected by the following invariants: ele-1
                TypeBackboneElement
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                115. Device.property
                Definition

                The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties.

                ShortThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
                Control0..0
                This element is affected by the following invariants: ele-1
                TypeBackboneElement
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                123. Device.patient
                Definition

                Patient information, If the device is affixed to a person.

                ShortPatient to whom Device is affixed
                Comments

                References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

                Control0..0
                This element is affected by the following invariants: ele-1
                TypeReference(Patient)
                Requirements

                If the device is implanted in a patient, then need to associate the device to the patient.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
                125. Device.owner
                Definition

                An organization that is responsible for the provision and ongoing maintenance of the device.

                ShortRéférence vers l'id de la structure FINESS ET à laquelle est rattaché cet équipement matériel lourd (idStructure).
                Comments

                References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

                Control0..1
                This element is affected by the following invariants: ele-1
                TypeReference(FR Core Organization Profile, AS Organization Profile)
                Must Supporttrue
                Must Support TypesNo must-support rules about the choice of types/profiles
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
                127. Device.contact
                Definition

                Contact details for an organization or a particular human that is responsible for the device.

                ShortDetails for human/organization for support
                Comments

                used for troubleshooting etc.

                Control0..0
                This element is affected by the following invariants: ele-1
                TypeContactPoint
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                cpt-2: A system is required if a value is provided. (value.empty() or system.exists())
                129. Device.location
                Definition

                The place where the device can be found.

                ShortWhere the device is found
                Comments

                References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

                Control0..0
                This element is affected by the following invariants: ele-1
                TypeReference(Location)
                Requirements

                Device.location can be used to track device location.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))
                131. Device.url
                Definition

                A network address on which the device may be contacted directly.

                ShortNetwork address to contact device
                Comments

                If the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved.

                Control0..0
                This element is affected by the following invariants: ele-1
                Typeuri
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                133. Device.note
                Definition

                Descriptive information, usage information or implantation information that is not captured in an existing element.

                ShortDevice notes and comments
                Comments

                For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible).

                Control0..0
                This element is affected by the following invariants: ele-1
                TypeAnnotation
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                135. Device.safety
                Definition

                Provides additional safety characteristics about a medical device. For example devices containing latex.

                ShortSafety Characteristics of Device
                Comments

                Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

                Control0..0
                This element is affected by the following invariants: ele-1
                TypeCodeableConcept
                Summarytrue
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                137. Device.parent
                Definition

                The parent device.

                ShortThe parent device
                Comments

                References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.

                Control0..0
                This element is affected by the following invariants: ele-1
                TypeReference(Device)
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ref-1: SHALL have a contained resource if a local reference is provided (reference.startsWith('#').not() or (reference.substring(1).trace('url') in %rootResource.contained.id.trace('ids')))