Terminologies de Santé
1.0.0 - final-text France flag

This page is part of the Guide d'implémentation des terminologies de Santé (v1.0.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

ValueSet: JDV Imagerie Objectif Reference CISIS

Official URL: https://smt.esante.gouv.fr/fhir/ValueSet/jdv-imagerie-objectif-reference-cisis Version: 20250606103857
Active as of 2025-06-06 Responsible: Agence du Numérique en Santé(ANS) -2 - 10 Rue d'Oradour-sur-Glane, 75015 Paris Computable Name: JdvImagerieObjectifReferenceCisis
Other Identifiers: OID:1.2.250.1.213.1.1.5.672

JDV Imagerie Objectif Reference CISIS

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Recherche en live sur le SMT

Indiquer un mot clé puis taper sur "enter" :
                    Requête sur le SMT
                

Logical Definition (CLD)

Generated Narrative: ValueSet jdv-imagerie-objectif-reference-cisis

version: 1; Last updated: 2025-06-06 11:04:53+0000; Language: fr-FR

Profil: Shareable ValueSet

  • Include ces codes sont définis dans http://dicom.nema.org/resources/ontology/DCM
    CodeDisplayDéfinition
    121079préliminaireInitial images used to establish a beginning condition that is used for comparison over time to look for changes. [Paraphrases NCI-PT (C1442488, UMLS, "Baseline"), which is defined as "An initial measurement that is taken at an early time point to represent a beginning condition, and is used for comparison over time to look for changes. For example, the size of a tumor will be measured before treatment (baseline) and then afterwards to see if the treatment had an effect. A starting point to which things may be compared."]
    121080Meilleure illustration de résultatA selection of composite instances that best illustrates a particular finding.
    121112Source de mesureImage or waveform used as source for measurement.
    121200Illustration de la ROIIllustration of a region of interest.

 

Expansion

ValueSet

Expansion performed internally based on codesystem DICOM v2022.4.20221006 (CodeSystem)

Ce jeu de valeur (ValueSet) contient 4 concepts

CodeSystèmeDisplay (fr-FR)Définition
  121079http://dicom.nema.org/resources/ontology/DCMpréliminaire

Initial images used to establish a beginning condition that is used for comparison over time to look for changes. [Paraphrases NCI-PT (C1442488, UMLS, "Baseline"), which is defined as "An initial measurement that is taken at an early time point to represent a beginning condition, and is used for comparison over time to look for changes. For example, the size of a tumor will be measured before treatment (baseline) and then afterwards to see if the treatment had an effect. A starting point to which things may be compared."]

  121080http://dicom.nema.org/resources/ontology/DCMMeilleure illustration de résultat

A selection of composite instances that best illustrates a particular finding.

  121112http://dicom.nema.org/resources/ontology/DCMSource de mesure

Image or waveform used as source for measurement.

  121200http://dicom.nema.org/resources/ontology/DCMIllustration de la ROI

Illustration of a region of interest.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code