Guide d'implémentation FHIR - Mesures de santé
3.1.0 - final-text France flag

This page is part of the Guide d'implémentation FHIR - Mesures de santé (v3.1.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions

Resource Profile: Pression Artérielle

Official URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-fr-observation-bp Version: 3.1.0
Active as of 2024-10-02 Computable Name: MesFrObservationBp

Profil de la ressource Observation pour définir une Pression Artérielle (acronyme : PA ou BP)

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from FRCoreObservationBpProfile

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation FRCoreObservationBpProfile
... meta
.... source 0..1 uri Uri identifiant les systèmes tiers ayant envoyé la ressource. L’uri est sous la forme d’une oid : « urn:oid:xx.xx.xx »
... Slices for extension Content/Rules for all slices
.... MesReasonForMeasurement 0..1 string Motif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
.... MesMomentOfMeasurement 0..1 CodeableConcept Moment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
... Slices for category Content/Rules for all slices
.... category:VSCat 1..1 CodeableConcept Classification of type of observation
..... coding
...... display 0..1 string Representation defined by the system
Required Pattern: vital-signs
... effective[x] 1..1 dateTime Often just a dateTime for Vital Signs
... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible)
... bodySite 0..1 CodeableConcept Observed body part
Binding: JDV_J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

.... coding
..... system 1..1 uri Identity of the terminology system
..... code 1..1 code Symbol in syntax defined by the system
... method S 0..1 CodeableConcept How it was done
Binding: JDV_J150-MethodBP-ENS (extensible)
... device S 0..1 Reference(PhdDevice) Dispositif utilisé pour récolter l'information. Ce dispositif peut être l'application permettant de renseigner la valeur. Si la mesure a été faite par un objet connecté (Profil PhdDevice), cette référence est obligatoire
... referenceRange
.... appliesTo 0..* CodeableConcept Reference range population
Binding: JDV_J148-ReferenceRangeAppliesTo-CISIS (required): https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS

..... coding
...... system 1..1 uri Identity of the terminology system
...... code 1..1 code Symbol in syntax defined by the system

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiterequiredJDV_J149-BodySiteBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS
Observation.methodextensibleJDV_J150-MethodBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS
Observation.referenceRange.appliesTorequiredJDV_J148-ReferenceRangeAppliesTo-CISIS
https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* FRCoreObservationBpProfile FHIR Blood Pressure Profile
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... Slices for extension Content/Rules for all slices
.... supportingInfo 0..1 Reference(Resource) Other information that may be relevant to this event.
URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo
.... MesReasonForMeasurement 0..1 string Motif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
.... MesMomentOfMeasurement 0..1 CodeableConcept Moment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... Slices for category S 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by value:coding.code, value:coding.system
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


.... category:VSCat S 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


..... coding SΣ 1..* Coding Code defined by a terminology system
...... system SΣ 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... code SΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: vital-signs
...... display Σ 0..1 string Representation defined by the system
Required Pattern: vital-signs
... code SΣ 1..1 CodeableConcept Blood Pressure
Binding: VitalSigns (extensible): This identifies the vital sign result type.

.... Slices for coding Σ 1..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:BPCode Σ 1..1 Coding Code defined by a terminology system
...... system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
...... code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 85354-9
... subject SΣ 1..1 Reference(FR Core Patient Profile) Who and/or what the observation is about
... effective[x] SΣC 1..1 dateTime Often just a dateTime for Vital Signs
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible)
... bodySite 0..1 CodeableConcept Observed body part
Binding: JDV_J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

... method S 0..1 CodeableConcept How it was done
Binding: JDV_J150-MethodBP-ENS (extensible)
... device S 0..1 Reference(PhdDevice) Dispositif utilisé pour récolter l'information. Ce dispositif peut être l'application permettant de renseigner la valeur. Si la mesure a été faite par un objet connecté (Profil PhdDevice), cette référence est obligatoire
... Slices for component SΣC 2..* BackboneElement Used when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
vs-3: If there is no a value a data absent reason must be present
.... component:All Slices Content/Rules for all slices
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

..... value[x] SΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... component:SystolicBP SΣC 1..1 BackboneElement Used when reporting systolic and diastolic blood pressure.
vs-3: If there is no a value a data absent reason must be present
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... Slices for coding Σ 1..* Coding Systolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:SBPCode Σ 1..1 Coding Systolic Blood Pressure
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8480-6
..... value[x] SΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... value[x]:All Slices Content/Rules for all slices
....... value SΣ 1..1 decimal Numerical value (with implicit precision)
....... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ 1..1 string Unit representation
....... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code SΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... component:DiastolicBP SΣC 1..1 BackboneElement Used when reporting diastolic blood pressure.
vs-3: If there is no a value a data absent reason must be present
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... Slices for coding Σ 1..* Coding Diastolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:DBPCode Σ 1..1 Coding Diastolic Blood Pressure
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8462-4
..... value[x] SΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... value[x]:All Slices Content/Rules for all slices
....... value SΣ 1..1 decimal Numerical value (with implicit precision)
....... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ 1..1 string Unit representation
....... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code SΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... component:MeanBP SΣC 0..1 BackboneElement Mean blood pressure
vs-3: If there is no a value a data absent reason must be present
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... Slices for coding Σ 1..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
....... coding:MBPCode Σ 1..1 Coding Code defined by a terminology system
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ code Σ 1..1 code Mean blood pressure
Fixed Value: 8478-0
..... value[x] SΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Observation.statusrequiredObservationStatus
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:VSCatpreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiterequiredJDV_J149-BodySiteBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS
Observation.methodextensibleJDV_J150-MethodBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS
Observation.component.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:SystolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:SystolicBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:DiastolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:DiastolicBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:MeanBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:MeanBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:MeanBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorObservationIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorObservationIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorObservationIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorObservationIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceObservationA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-6errorObservationdataAbsentReason SHALL only be present if Observation.value[x] is not present
: dataAbsentReason.empty() or value.empty()
obs-7errorObservationIf Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
: value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
vs-1errorObservation.effective[x]if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
: $this is dateTime implies $this.toString().length() >= 10
vs-2errorObservationIf there is no component or hasMember element then either a value[x] or a data absent reason must be present.
: (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
vs-3errorObservation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanBPIf there is no a value a data absent reason must be present
: value.exists() or dataAbsentReason.exists()
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* FRCoreObservationBpProfile FHIR Blood Pressure Profile
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... versionId Σ 0..1 id Version specific identifier
.... lastUpdated Σ 0..1 instant When the resource version last changed
.... source Σ 0..1 uri Uri identifiant les systèmes tiers ayant envoyé la ressource. L’uri est sous la forme d’une oid : « urn:oid:xx.xx.xx »
.... Slices for profile Σ 0..* canonical(StructureDefinition) Profiles this resource claims to conform to
Slice: Unordered, Open by value:$this
..... profile:fr-canonical Σ 0..1 canonical(StructureDefinition) Profiles this resource claims to conform to

Required Pattern: https://hl7.fr/ig/fhir/core/StructureDefinition/fr-core-observation-bp
.... security Σ 0..* Coding Security Labels applied to this resource
Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System.


.... tag Σ 0..* Coding Tags applied to this resource
Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones".


... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... Slices for extension 0..* Extension Extension
Slice: Unordered, Open by value:url
.... supportingInfo 0..1 Reference(Resource) Other information that may be relevant to this event.
URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo
.... MesReasonForMeasurement 0..1 string Motif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
.... MesMomentOfMeasurement 0..1 CodeableConcept Moment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier Σ 0..* Identifier Business Identifier for observation
... basedOn Σ 0..* Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) Fulfills plan, proposal or order
... partOf Σ 0..* Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Part of referenced event
... status ?!SΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required)
... Slices for category S 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by value:coding.code, value:coding.system
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


.... category:VSCat S 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... coding SΣ 1..* Coding Code defined by a terminology system
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system SΣ 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... version Σ 0..1 string Version of the system - if relevant
...... code SΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: vital-signs
...... display Σ 0..1 string Representation defined by the system
Required Pattern: vital-signs
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... text Σ 0..1 string Plain text representation of the concept
... code SΣ 1..1 CodeableConcept Blood Pressure
Binding: VitalSigns (extensible): This identifies the vital sign result type.

.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... Slices for coding Σ 1..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:BPCode Σ 1..1 Coding Code defined by a terminology system
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
...... version Σ 0..1 string Version of the system - if relevant
...... code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 85354-9
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
.... text Σ 0..1 string Plain text representation of the concept
... subject SΣ 1..1 Reference(FR Core Patient Profile) Who and/or what the observation is about
... focus Σ 0..* Reference(Resource) What the observation is about, when it is not about the subject of record
... encounter Σ 0..1 Reference(FR Core Encounter Profile) Healthcare event during which this observation is made
... effective[x] SΣC 1..1 dateTime Often just a dateTime for Vital Signs
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
... issued Σ 0..1 instant Date/Time this version was made available
... performer Σ 0..* Reference(CareTeam | FR Core Patient Profile | FR Core Practitioner Profile | PractitionerRole | FR Core Organization Profile | FR Core Related Person Profile) Who is responsible for the observation
... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible)
... note 0..* Annotation Comments about the observation
... bodySite 0..1 CodeableConcept Observed body part
Binding: JDV_J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... coding Σ 0..* Coding Code defined by a terminology system
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... system Σ 1..1 uri Identity of the terminology system
..... version Σ 0..1 string Version of the system - if relevant
..... code Σ 1..1 code Symbol in syntax defined by the system
..... display Σ 0..1 string Representation defined by the system
..... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
.... text Σ 0..1 string Plain text representation of the concept
... method S 0..1 CodeableConcept How it was done
Binding: JDV_J150-MethodBP-ENS (extensible)
... specimen 0..1 Reference(Specimen) Specimen used for this observation
... device S 0..1 Reference(PhdDevice) Dispositif utilisé pour récolter l'information. Ce dispositif peut être l'application permettant de renseigner la valeur. Si la mesure a été faite par un objet connecté (Profil PhdDevice), cette référence est obligatoire
... referenceRange C 0..* BackboneElement Provides guide for interpretation
obs-3: Must have at least a low or a high or text
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... low C 0..1 SimpleQuantity Low Range, if relevant
.... high C 0..1 SimpleQuantity High Range, if relevant
.... type 0..1 CodeableConcept Reference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..* CodeableConcept Reference range population
Binding: JDV_J148-ReferenceRangeAppliesTo-CISIS (required): https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS


..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... coding Σ 0..* Coding Code defined by a terminology system
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ 1..1 uri Identity of the terminology system
...... version Σ 0..1 string Version of the system - if relevant
...... code Σ 1..1 code Symbol in syntax defined by the system
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... text Σ 0..1 string Plain text representation of the concept
.... age 0..1 Range Applicable age range, if relevant
.... text 0..1 string Text based reference range in an observation
... hasMember Σ 0..* Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) Used when reporting vital signs panel components
... derivedFrom Σ 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) Related measurements the observation is made from
... Slices for component SΣC 2..* BackboneElement Used when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
vs-3: If there is no a value a data absent reason must be present
.... component:All Slices Content/Rules for all slices
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

..... value[x] SΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:SystolicBP SΣC 1..1 BackboneElement Used when reporting systolic and diastolic blood pressure.
vs-3: If there is no a value a data absent reason must be present
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 1..* Coding Systolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:SBPCode Σ 1..1 Coding Systolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8480-6
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... value[x]:All Slices Content/Rules for all slices
....... id 0..1 string Unique id for inter-element referencing
....... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
....... value SΣ 1..1 decimal Numerical value (with implicit precision)
....... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ 1..1 string Unit representation
....... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code SΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:DiastolicBP SΣC 1..1 BackboneElement Used when reporting diastolic blood pressure.
vs-3: If there is no a value a data absent reason must be present
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 1..* Coding Diastolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:DBPCode Σ 1..1 Coding Diastolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8462-4
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... value[x]:All Slices Content/Rules for all slices
....... id 0..1 string Unique id for inter-element referencing
....... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
....... value SΣ 1..1 decimal Numerical value (with implicit precision)
....... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ 1..1 string Unit representation
....... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code SΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:MeanBP SΣC 0..1 BackboneElement Mean blood pressure
vs-3: If there is no a value a data absent reason must be present
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 1..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
....... coding:MBPCode Σ 1..1 Coding Code defined by a terminology system
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Mean blood pressure
Fixed Value: 8478-0
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Observation.meta.securityextensibleAll Security Labels
http://hl7.org/fhir/ValueSet/security-labels
from the FHIR Standard
Observation.meta.tagexampleCommonTags
http://hl7.org/fhir/ValueSet/common-tags
from the FHIR Standard
Observation.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Observation.statusrequiredObservationStatus
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:VSCatpreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiterequiredJDV_J149-BodySiteBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS
Observation.methodextensibleJDV_J150-MethodBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS
Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
http://hl7.org/fhir/ValueSet/referencerange-meaning
from the FHIR Standard
Observation.referenceRange.appliesTorequiredJDV_J148-ReferenceRangeAppliesTo-CISIS
https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS
Observation.component.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:SystolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:SystolicBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:SystolicBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:DiastolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:DiastolicBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:DiastolicBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:MeanBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:MeanBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:MeanBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:MeanBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorObservationIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorObservationIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorObservationIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorObservationIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceObservationA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-3errorObservation.referenceRangeMust have at least a low or a high or text
: low.exists() or high.exists() or text.exists()
obs-6errorObservationdataAbsentReason SHALL only be present if Observation.value[x] is not present
: dataAbsentReason.empty() or value.empty()
obs-7errorObservationIf Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
: value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
vs-1errorObservation.effective[x]if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
: $this is dateTime implies $this.toString().length() >= 10
vs-2errorObservationIf there is no component or hasMember element then either a value[x] or a data absent reason must be present.
: (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
vs-3errorObservation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanBPIf there is no a value a data absent reason must be present
: value.exists() or dataAbsentReason.exists()

Differential View

This structure is derived from FRCoreObservationBpProfile

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation FRCoreObservationBpProfile
... meta
.... source 0..1 uri Uri identifiant les systèmes tiers ayant envoyé la ressource. L’uri est sous la forme d’une oid : « urn:oid:xx.xx.xx »
... Slices for extension Content/Rules for all slices
.... MesReasonForMeasurement 0..1 string Motif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
.... MesMomentOfMeasurement 0..1 CodeableConcept Moment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
... Slices for category Content/Rules for all slices
.... category:VSCat 1..1 CodeableConcept Classification of type of observation
..... coding
...... display 0..1 string Representation defined by the system
Required Pattern: vital-signs
... effective[x] 1..1 dateTime Often just a dateTime for Vital Signs
... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible)
... bodySite 0..1 CodeableConcept Observed body part
Binding: JDV_J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

.... coding
..... system 1..1 uri Identity of the terminology system
..... code 1..1 code Symbol in syntax defined by the system
... method S 0..1 CodeableConcept How it was done
Binding: JDV_J150-MethodBP-ENS (extensible)
... device S 0..1 Reference(PhdDevice) Dispositif utilisé pour récolter l'information. Ce dispositif peut être l'application permettant de renseigner la valeur. Si la mesure a été faite par un objet connecté (Profil PhdDevice), cette référence est obligatoire
... referenceRange
.... appliesTo 0..* CodeableConcept Reference range population
Binding: JDV_J148-ReferenceRangeAppliesTo-CISIS (required): https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS

..... coding
...... system 1..1 uri Identity of the terminology system
...... code 1..1 code Symbol in syntax defined by the system

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiterequiredJDV_J149-BodySiteBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS
Observation.methodextensibleJDV_J150-MethodBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS
Observation.referenceRange.appliesTorequiredJDV_J148-ReferenceRangeAppliesTo-CISIS
https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* FRCoreObservationBpProfile FHIR Blood Pressure Profile
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... Slices for extension Content/Rules for all slices
.... supportingInfo 0..1 Reference(Resource) Other information that may be relevant to this event.
URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo
.... MesReasonForMeasurement 0..1 string Motif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
.... MesMomentOfMeasurement 0..1 CodeableConcept Moment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... Slices for category S 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by value:coding.code, value:coding.system
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


.... category:VSCat S 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


..... coding SΣ 1..* Coding Code defined by a terminology system
...... system SΣ 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... code SΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: vital-signs
...... display Σ 0..1 string Representation defined by the system
Required Pattern: vital-signs
... code SΣ 1..1 CodeableConcept Blood Pressure
Binding: VitalSigns (extensible): This identifies the vital sign result type.

.... Slices for coding Σ 1..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:BPCode Σ 1..1 Coding Code defined by a terminology system
...... system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
...... code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 85354-9
... subject SΣ 1..1 Reference(FR Core Patient Profile) Who and/or what the observation is about
... effective[x] SΣC 1..1 dateTime Often just a dateTime for Vital Signs
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible)
... bodySite 0..1 CodeableConcept Observed body part
Binding: JDV_J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

... method S 0..1 CodeableConcept How it was done
Binding: JDV_J150-MethodBP-ENS (extensible)
... device S 0..1 Reference(PhdDevice) Dispositif utilisé pour récolter l'information. Ce dispositif peut être l'application permettant de renseigner la valeur. Si la mesure a été faite par un objet connecté (Profil PhdDevice), cette référence est obligatoire
... Slices for component SΣC 2..* BackboneElement Used when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
vs-3: If there is no a value a data absent reason must be present
.... component:All Slices Content/Rules for all slices
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

..... value[x] SΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... component:SystolicBP SΣC 1..1 BackboneElement Used when reporting systolic and diastolic blood pressure.
vs-3: If there is no a value a data absent reason must be present
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... Slices for coding Σ 1..* Coding Systolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:SBPCode Σ 1..1 Coding Systolic Blood Pressure
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8480-6
..... value[x] SΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... value[x]:All Slices Content/Rules for all slices
....... value SΣ 1..1 decimal Numerical value (with implicit precision)
....... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ 1..1 string Unit representation
....... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code SΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... component:DiastolicBP SΣC 1..1 BackboneElement Used when reporting diastolic blood pressure.
vs-3: If there is no a value a data absent reason must be present
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... Slices for coding Σ 1..* Coding Diastolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:DBPCode Σ 1..1 Coding Diastolic Blood Pressure
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8462-4
..... value[x] SΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... value[x]:All Slices Content/Rules for all slices
....... value SΣ 1..1 decimal Numerical value (with implicit precision)
....... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ 1..1 string Unit representation
....... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code SΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... component:MeanBP SΣC 0..1 BackboneElement Mean blood pressure
vs-3: If there is no a value a data absent reason must be present
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... Slices for coding Σ 1..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
....... coding:MBPCode Σ 1..1 Coding Code defined by a terminology system
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ code Σ 1..1 code Mean blood pressure
Fixed Value: 8478-0
..... value[x] SΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Observation.statusrequiredObservationStatus
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:VSCatpreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiterequiredJDV_J149-BodySiteBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS
Observation.methodextensibleJDV_J150-MethodBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS
Observation.component.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:SystolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:SystolicBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:DiastolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:DiastolicBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:MeanBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:MeanBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:MeanBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorObservationIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorObservationIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorObservationIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorObservationIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceObservationA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-6errorObservationdataAbsentReason SHALL only be present if Observation.value[x] is not present
: dataAbsentReason.empty() or value.empty()
obs-7errorObservationIf Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
: value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
vs-1errorObservation.effective[x]if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
: $this is dateTime implies $this.toString().length() >= 10
vs-2errorObservationIf there is no component or hasMember element then either a value[x] or a data absent reason must be present.
: (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
vs-3errorObservation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanBPIf there is no a value a data absent reason must be present
: value.exists() or dataAbsentReason.exists()

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* FRCoreObservationBpProfile FHIR Blood Pressure Profile
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... versionId Σ 0..1 id Version specific identifier
.... lastUpdated Σ 0..1 instant When the resource version last changed
.... source Σ 0..1 uri Uri identifiant les systèmes tiers ayant envoyé la ressource. L’uri est sous la forme d’une oid : « urn:oid:xx.xx.xx »
.... Slices for profile Σ 0..* canonical(StructureDefinition) Profiles this resource claims to conform to
Slice: Unordered, Open by value:$this
..... profile:fr-canonical Σ 0..1 canonical(StructureDefinition) Profiles this resource claims to conform to

Required Pattern: https://hl7.fr/ig/fhir/core/StructureDefinition/fr-core-observation-bp
.... security Σ 0..* Coding Security Labels applied to this resource
Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System.


.... tag Σ 0..* Coding Tags applied to this resource
Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones".


... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... Slices for extension 0..* Extension Extension
Slice: Unordered, Open by value:url
.... supportingInfo 0..1 Reference(Resource) Other information that may be relevant to this event.
URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo
.... MesReasonForMeasurement 0..1 string Motif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
.... MesMomentOfMeasurement 0..1 CodeableConcept Moment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier Σ 0..* Identifier Business Identifier for observation
... basedOn Σ 0..* Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) Fulfills plan, proposal or order
... partOf Σ 0..* Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Part of referenced event
... status ?!SΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required)
... Slices for category S 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by value:coding.code, value:coding.system
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


.... category:VSCat S 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... coding SΣ 1..* Coding Code defined by a terminology system
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system SΣ 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... version Σ 0..1 string Version of the system - if relevant
...... code SΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: vital-signs
...... display Σ 0..1 string Representation defined by the system
Required Pattern: vital-signs
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... text Σ 0..1 string Plain text representation of the concept
... code SΣ 1..1 CodeableConcept Blood Pressure
Binding: VitalSigns (extensible): This identifies the vital sign result type.

.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... Slices for coding Σ 1..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:BPCode Σ 1..1 Coding Code defined by a terminology system
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
...... version Σ 0..1 string Version of the system - if relevant
...... code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 85354-9
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
.... text Σ 0..1 string Plain text representation of the concept
... subject SΣ 1..1 Reference(FR Core Patient Profile) Who and/or what the observation is about
... focus Σ 0..* Reference(Resource) What the observation is about, when it is not about the subject of record
... encounter Σ 0..1 Reference(FR Core Encounter Profile) Healthcare event during which this observation is made
... effective[x] SΣC 1..1 dateTime Often just a dateTime for Vital Signs
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
... issued Σ 0..1 instant Date/Time this version was made available
... performer Σ 0..* Reference(CareTeam | FR Core Patient Profile | FR Core Practitioner Profile | PractitionerRole | FR Core Organization Profile | FR Core Related Person Profile) Who is responsible for the observation
... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible)
... note 0..* Annotation Comments about the observation
... bodySite 0..1 CodeableConcept Observed body part
Binding: JDV_J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... coding Σ 0..* Coding Code defined by a terminology system
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... system Σ 1..1 uri Identity of the terminology system
..... version Σ 0..1 string Version of the system - if relevant
..... code Σ 1..1 code Symbol in syntax defined by the system
..... display Σ 0..1 string Representation defined by the system
..... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
.... text Σ 0..1 string Plain text representation of the concept
... method S 0..1 CodeableConcept How it was done
Binding: JDV_J150-MethodBP-ENS (extensible)
... specimen 0..1 Reference(Specimen) Specimen used for this observation
... device S 0..1 Reference(PhdDevice) Dispositif utilisé pour récolter l'information. Ce dispositif peut être l'application permettant de renseigner la valeur. Si la mesure a été faite par un objet connecté (Profil PhdDevice), cette référence est obligatoire
... referenceRange C 0..* BackboneElement Provides guide for interpretation
obs-3: Must have at least a low or a high or text
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... low C 0..1 SimpleQuantity Low Range, if relevant
.... high C 0..1 SimpleQuantity High Range, if relevant
.... type 0..1 CodeableConcept Reference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..* CodeableConcept Reference range population
Binding: JDV_J148-ReferenceRangeAppliesTo-CISIS (required): https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS


..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... coding Σ 0..* Coding Code defined by a terminology system
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ 1..1 uri Identity of the terminology system
...... version Σ 0..1 string Version of the system - if relevant
...... code Σ 1..1 code Symbol in syntax defined by the system
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... text Σ 0..1 string Plain text representation of the concept
.... age 0..1 Range Applicable age range, if relevant
.... text 0..1 string Text based reference range in an observation
... hasMember Σ 0..* Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) Used when reporting vital signs panel components
... derivedFrom Σ 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) Related measurements the observation is made from
... Slices for component SΣC 2..* BackboneElement Used when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
vs-3: If there is no a value a data absent reason must be present
.... component:All Slices Content/Rules for all slices
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

..... value[x] SΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:SystolicBP SΣC 1..1 BackboneElement Used when reporting systolic and diastolic blood pressure.
vs-3: If there is no a value a data absent reason must be present
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 1..* Coding Systolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:SBPCode Σ 1..1 Coding Systolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8480-6
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... value[x]:All Slices Content/Rules for all slices
....... id 0..1 string Unique id for inter-element referencing
....... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
....... value SΣ 1..1 decimal Numerical value (with implicit precision)
....... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ 1..1 string Unit representation
....... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code SΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:DiastolicBP SΣC 1..1 BackboneElement Used when reporting diastolic blood pressure.
vs-3: If there is no a value a data absent reason must be present
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 1..* Coding Diastolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:DBPCode Σ 1..1 Coding Diastolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8462-4
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... value[x]:All Slices Content/Rules for all slices
....... id 0..1 string Unique id for inter-element referencing
....... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
....... value SΣ 1..1 decimal Numerical value (with implicit precision)
....... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ 1..1 string Unit representation
....... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code SΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:MeanBP SΣC 0..1 BackboneElement Mean blood pressure
vs-3: If there is no a value a data absent reason must be present
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 1..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
....... coding:MBPCode Σ 1..1 Coding Code defined by a terminology system
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Mean blood pressure
Fixed Value: 8478-0
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Observation.meta.securityextensibleAll Security Labels
http://hl7.org/fhir/ValueSet/security-labels
from the FHIR Standard
Observation.meta.tagexampleCommonTags
http://hl7.org/fhir/ValueSet/common-tags
from the FHIR Standard
Observation.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Observation.statusrequiredObservationStatus
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:VSCatpreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiterequiredJDV_J149-BodySiteBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS
Observation.methodextensibleJDV_J150-MethodBP-ENS
https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS
Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
http://hl7.org/fhir/ValueSet/referencerange-meaning
from the FHIR Standard
Observation.referenceRange.appliesTorequiredJDV_J148-ReferenceRangeAppliesTo-CISIS
https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS
Observation.component.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:SystolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:SystolicBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:SystolicBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:DiastolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:DiastolicBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:DiastolicBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:MeanBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:MeanBP.value[x]requiredVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:MeanBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:MeanBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorObservationIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorObservationIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorObservationIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorObservationIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceObservationA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-3errorObservation.referenceRangeMust have at least a low or a high or text
: low.exists() or high.exists() or text.exists()
obs-6errorObservationdataAbsentReason SHALL only be present if Observation.value[x] is not present
: dataAbsentReason.empty() or value.empty()
obs-7errorObservationIf Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
: value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
vs-1errorObservation.effective[x]if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
: $this is dateTime implies $this.toString().length() >= 10
vs-2errorObservationIf there is no component or hasMember element then either a value[x] or a data absent reason must be present.
: (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
vs-3errorObservation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanBPIf there is no a value a data absent reason must be present
: value.exists() or dataAbsentReason.exists()

 

Other representations of profile: CSV, Excel, Schematron