Guide d'implémentation FHIR - Mesures de santé
3.0.0 - ci-build

This page is part of the Guide d'implémentation FHIR - Mesures de santé (v3.0.0: draft Ballot 1) based on FHIR R4. . For a full list of available versions, see the Directory of published versions

Resource Profile: MesFrObservationBp

Official URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-fr-observation-bp Version: 3.0.0
Active as of 2023-04-06 Computable Name: MesFrObservationBp

Pression artérielle - profil créé pour l’alimentation de l’Espace Numérique de Santé

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from FrObservationBp

Summary

Mandatory: 3 elements (7 nested mandatory elements)
Must-Support: 1 element

Structures

This structure refers to these other structures:

Extensions

This structure refers to these extensions:

Slices

This structure defines the following Slices:

  • The element Observation.meta.profile is sliced based on the value of value:$this

This structure is derived from FrObservationBp

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..*FrObservationBpMeasurements and simple assertions
... meta 1..1MetaMetadata about the resource
.... source 0..1uriUri identifiant les systèmes tiers ayant envoyé la ressource.
.... Slices for profile 1..*canonical(StructureDefinition)Profiles this resource claims to conform to
Slice: Unordered, Open by value:$this
..... profile:MesFrObservationBp S1..1canonical(StructureDefinition)Profiles this resource claims to conform to
Required Pattern: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-fr-observation-bp
... MesReasonForMeasurement 0..1stringMotif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
... MesMomentOfMeasurement 0..1CodeableConceptMoment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
.... coding
..... display 0..1stringRepresentation defined by the system
Required Pattern: Signes vitaux
... subject 0..1Reference(FrPatient)Who and/or what the observation is about
... effective[x] 1..1dateTimeOften just a dateTime for Vital Signs
... interpretation 0..*CodeableConceptNon renseigné
... bodySite 0..1CodeableConceptObserved body part
Binding: https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

.... coding
..... system 1..1uriIdentity of the terminology system
..... code 1..1codeSymbol in syntax defined by the system
... method 0..1CodeableConceptHow it was done
Binding: https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS

.... coding
..... system 1..1uriIdentity of the terminology system
..... code 1..1codeSymbol in syntax defined by the system
... device 0..1Reference(PhdDevice)(Measurement) Device
.... reference 1..1stringLiteral reference, Relative, internal or absolute URL
... referenceRange
.... appliesTo 0..*CodeableConceptReference range population
Binding: https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS (required): https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS

..... coding
...... system 1..1uriIdentity of the terminology system
...... code 1..1codeSymbol in syntax defined by the system
... component 2..*BackboneElementUsed when reporting systolic and diastolic blood pressure.
.... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C0..*FrObservationBpMeasurements and simple assertions
... id Σ0..1idLogical id of this artifact
... meta Σ1..1MetaMetadata about the resource
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... versionId Σ0..1idVersion specific identifier
.... lastUpdated Σ0..1instantWhen the resource version last changed
.... source Σ0..1uriUri identifiant les systèmes tiers ayant envoyé la ressource.
.... Slices for profile Σ1..*canonical(StructureDefinition)Profiles this resource claims to conform to
Slice: Unordered, Open by value:$this
..... profile:MesFrObservationBp SΣ1..1canonical(StructureDefinition)Profiles this resource claims to conform to

Required Pattern: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-fr-observation-bp
.... security Σ0..*CodingSecurity Labels applied to this resource
Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System.


.... tag Σ0..*CodingTags applied to this resource
Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones".


... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguagesMax Binding
... text 0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... Slices for extension 0..*ExtensionExtension
Slice: Unordered, Open by value:url
... supportingInfo 0..1Reference(Resource)Other information that may be relevant to this event.
URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo
... MesReasonForMeasurement 0..1stringMotif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
... MesMomentOfMeasurement 0..1CodeableConceptMoment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... identifier Σ0..*IdentifierBusiness Identifier for observation
... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
... status ?!Σ1..1coderegistered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.

... Slices for category 1..*CodeableConceptClassification of type of observation
Slice: Unordered, Open by value:coding.code, value:coding.system
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


.... category:VSCat 1..1CodeableConceptClassification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... coding Σ1..*CodingCode defined by a terminology system
...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ1..1uriIdentity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... version Σ0..1stringVersion of the system - if relevant
...... code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: vital-signs
...... display Σ0..1stringRepresentation defined by the system
Required Pattern: Signes vitaux
...... userSelected Σ0..1booleanIf this coding was chosen directly by the user
..... text Σ0..1stringPlain text representation of the concept
... code Σ1..1CodeableConceptBlood pressure code
Binding: VitalSigns (extensible)
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... Slices for coding Σ0..*CodingCode defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:BPCode Σ1..1CodingCode defined by a terminology system
...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
...... version Σ0..1stringVersion of the system - if relevant
...... code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: 85354-9
...... display Σ0..1stringRepresentation defined by the system
...... userSelected Σ0..1booleanIf this coding was chosen directly by the user
.... text Σ0..1stringPlain text representation of the concept
... subject Σ0..1Reference(FrPatient)Who and/or what the observation is about
... focus ΣTU0..*Reference(Resource)What the observation is about, when it is not about the subject of record
... encounter Σ0..1Reference(FrEncounter)Healthcare event during which this observation is made
... effective[x] Σ1..1dateTimeOften just a dateTime for Vital Signs
... issued Σ0..1instantDate/Time this version was made available
... performer Σ0..*Reference(CareTeam | FrPatient | FrPractitioner | FrPractitionerRoleExercice | FrOrganization | FrRelatedPerson)Who is responsible for the observation
... dataAbsentReason C0..1CodeableConceptWhy the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..*CodeableConceptNon renseigné
Binding: http://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation (extensible)
... note 0..*AnnotationComments about the observation
... bodySite 0..1CodeableConceptObserved body part
Binding: https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... coding Σ0..*CodingCode defined by a terminology system
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... system Σ1..1uriIdentity of the terminology system
..... version Σ0..1stringVersion of the system - if relevant
..... code Σ1..1codeSymbol in syntax defined by the system
..... display Σ0..1stringRepresentation defined by the system
..... userSelected Σ0..1booleanIf this coding was chosen directly by the user
.... text Σ0..1stringPlain text representation of the concept
... method 0..1CodeableConceptHow it was done
Binding: https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS

.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... coding Σ0..*CodingCode defined by a terminology system
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... system Σ1..1uriIdentity of the terminology system
..... version Σ0..1stringVersion of the system - if relevant
..... code Σ1..1codeSymbol in syntax defined by the system
..... display Σ0..1stringRepresentation defined by the system
..... userSelected Σ0..1booleanIf this coding was chosen directly by the user
.... text Σ0..1stringPlain text representation of the concept
... specimen 0..1Reference(Specimen)Specimen used for this observation
... device 0..1Reference(PhdDevice)(Measurement) Device
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... reference ΣC1..1stringLiteral reference, Relative, internal or absolute URL
.... type Σ0..1uriType the reference refers to (e.g. "Patient")
Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model).

.... identifier Σ0..1IdentifierLogical reference, when literal reference is not known
.... display Σ0..1stringText alternative for the resource
... referenceRange C0..*BackboneElementProvides guide for interpretation
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... low C0..1SimpleQuantityLow Range, if relevant
.... high C0..1SimpleQuantityHigh Range, if relevant
.... type 0..1CodeableConceptReference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..*CodeableConceptReference range population
Binding: https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS (required): https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS


..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... coding Σ0..*CodingCode defined by a terminology system
...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ1..1uriIdentity of the terminology system
...... version Σ0..1stringVersion of the system - if relevant
...... code Σ1..1codeSymbol in syntax defined by the system
...... display Σ0..1stringRepresentation defined by the system
...... userSelected Σ0..1booleanIf this coding was chosen directly by the user
..... text Σ0..1stringPlain text representation of the concept
.... age 0..1RangeApplicable age range, if relevant
.... text 0..1stringText based reference range in an observation
... hasMember Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Related resource that belongs to the Observation group
... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)Related measurements the observation is made from
... Slices for component Σ2..*BackboneElementUsed when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
.... component:All Slices Content/Rules for all slices
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... code Σ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

..... value[x] Σ0..1Actual component result
...... valueQuantityQuantity
...... valueCodeableConceptCodeableConcept
...... valueStringstring
...... valueBooleanboolean
...... valueIntegerinteger
...... valueRangeRange
...... valueRatioRatio
...... valueSampledDataSampledData
...... valueTimetime
...... valueDateTimedateTime
...... valuePeriodPeriod
..... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
.... component:SystolicBP SΣ1..1BackboneElementUsed when reporting systolic blood pressure.
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... code SΣ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ0..*CodingSystolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:SBPCode Σ1..1CodingCode defined by a terminology system
........ id 0..1stringUnique id for inter-element referencing
........ extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
........ version Σ0..1stringVersion of the system - if relevant
........ code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: 8480-6
........ display Σ0..1stringRepresentation defined by the system
........ userSelected Σ0..1booleanIf this coding was chosen directly by the user
...... text Σ0..1stringPlain text representation of the concept
..... Slices for value[x] SΣ0..1Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantityQuantity
...... valueCodeableConceptCodeableConcept
...... valueStringstring
...... valueBooleanboolean
...... valueIntegerinteger
...... valueRangeRange
...... valueRatioRatio
...... valueSampledDataSampledData
...... valueTimetime
...... valueDateTimedateTime
...... valuePeriodPeriod
...... value[x]:valueQuantity Σ0..1QuantityActual component result
....... id 0..1stringUnique id for inter-element referencing
....... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
....... value SΣ1..1decimalNumerical value (with implicit precision)
....... comparator ?!Σ0..1code< | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ1..1stringUnit representation
Fixed Value: mm[Hg]
....... system ΣC1..1uriSystem that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code Σ1..1codeCoded form of the unit
Fixed Value: mm[Hg]
..... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: http://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation (extensible)
..... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
.... component:DiastolicBP SΣ1..1BackboneElementUsed when reporting diastolic blood pressure.
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... code SΣ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ0..*CodingCode defined by a terminology system
Slice: Unordered, Open by value:code, value:system
....... coding:DBPCode Σ1..1CodingCode defined by a terminology system
........ id 0..1stringUnique id for inter-element referencing
........ extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
........ version Σ0..1stringVersion of the system - if relevant
........ code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: 8462-4
........ display Σ0..1stringRepresentation defined by the system
........ userSelected Σ0..1booleanIf this coding was chosen directly by the user
...... text Σ0..1stringPlain text representation of the concept
..... Slices for value[x] SΣ0..1Vital Sign Value recorded with UCUM.
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantityQuantity
...... valueCodeableConceptCodeableConcept
...... valueStringstring
...... valueBooleanboolean
...... valueIntegerinteger
...... valueRangeRange
...... valueRatioRatio
...... valueSampledDataSampledData
...... valueTimetime
...... valueDateTimedateTime
...... valuePeriodPeriod
...... value[x]:valueQuantity Σ0..1QuantityActual component result
....... id 0..1stringUnique id for inter-element referencing
....... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
....... value Σ1..1decimalNumerical value (with implicit precision)
....... comparator ?!Σ0..1code< | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit Σ1..1stringUnit representation
Fixed Value: mm[Hg]
....... system ΣC1..1uriSystem that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code Σ1..1codeCoded form of the unit
Fixed Value: mm[Hg]
..... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: http://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation (extensible)
..... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
.... component:MeanBP Σ0..1BackboneElementMean blood pressure
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... code SΣ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ0..*CodingCode defined by a terminology system
Slice: Unordered, Open by value:code, value:system
....... coding:MBPCode Σ1..1CodingCode defined by a terminology system
........ id 0..1stringUnique id for inter-element referencing
........ extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
........ version Σ0..1stringVersion of the system - if relevant
........ code Σ1..1codeMean blood pressure
Fixed Value: 8478-0
........ display Σ0..1stringRepresentation defined by the system
........ userSelected Σ0..1booleanIf this coding was chosen directly by the user
...... text Σ0..1stringPlain text representation of the concept
..... value[x] Σ0..1Actual component result
...... valueQuantityQuantity
...... valueCodeableConceptCodeableConcept
...... valueStringstring
...... valueBooleanboolean
...... valueIntegerinteger
...... valueRangeRange
...... valueRatioRatio
...... valueSampledDataSampledData
...... valueTimetime
...... valueDateTimedateTime
...... valuePeriodPeriod
..... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: http://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation (extensible)
..... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C0..*FrObservationBpMeasurements and simple assertions
... meta Σ1..1MetaMetadata about the resource
.... profile:MesFrObservationBp Σ1..1canonical(StructureDefinition)Profiles this resource claims to conform to

Required Pattern: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-fr-observation-bp
... component:SystolicBP Σ1..1BackboneElementUsed when reporting systolic blood pressure.
.... code Σ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

.... Slices for value[x] Σ0..1Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

..... valueQuantityQuantity
..... valueCodeableConceptCodeableConcept
..... valueStringstring
..... valueBooleanboolean
..... valueIntegerinteger
..... valueRangeRange
..... valueRatioRatio
..... valueSampledDataSampledData
..... valueTimetime
..... valueDateTimedateTime
..... valuePeriodPeriod
..... value[x]:valueQuantity Σ0..1QuantityActual component result
...... value Σ1..1decimalNumerical value (with implicit precision)
...... unit Σ1..1stringUnit representation
Fixed Value: mm[Hg]
... component:DiastolicBP Σ1..1BackboneElementUsed when reporting diastolic blood pressure.
.... code Σ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

.... value[x] Σ0..1Vital Sign Value recorded with UCUM.
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

..... valueQuantityQuantity
..... valueCodeableConceptCodeableConcept
..... valueStringstring
..... valueBooleanboolean
..... valueIntegerinteger
..... valueRangeRange
..... valueRatioRatio
..... valueSampledDataSampledData
..... valueTimetime
..... valueDateTimedateTime
..... valuePeriodPeriod
.... code Σ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.


doco Documentation for this format

This structure is derived from FrObservationBp

Summary

Mandatory: 3 elements (7 nested mandatory elements)
Must-Support: 1 element

Structures

This structure refers to these other structures:

Extensions

This structure refers to these extensions:

Slices

This structure defines the following Slices:

  • The element Observation.meta.profile is sliced based on the value of value:$this

Differential View

This structure is derived from FrObservationBp

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..*FrObservationBpMeasurements and simple assertions
... meta 1..1MetaMetadata about the resource
.... source 0..1uriUri identifiant les systèmes tiers ayant envoyé la ressource.
.... Slices for profile 1..*canonical(StructureDefinition)Profiles this resource claims to conform to
Slice: Unordered, Open by value:$this
..... profile:MesFrObservationBp S1..1canonical(StructureDefinition)Profiles this resource claims to conform to
Required Pattern: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-fr-observation-bp
... MesReasonForMeasurement 0..1stringMotif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
... MesMomentOfMeasurement 0..1CodeableConceptMoment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
.... coding
..... display 0..1stringRepresentation defined by the system
Required Pattern: Signes vitaux
... subject 0..1Reference(FrPatient)Who and/or what the observation is about
... effective[x] 1..1dateTimeOften just a dateTime for Vital Signs
... interpretation 0..*CodeableConceptNon renseigné
... bodySite 0..1CodeableConceptObserved body part
Binding: https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

.... coding
..... system 1..1uriIdentity of the terminology system
..... code 1..1codeSymbol in syntax defined by the system
... method 0..1CodeableConceptHow it was done
Binding: https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS

.... coding
..... system 1..1uriIdentity of the terminology system
..... code 1..1codeSymbol in syntax defined by the system
... device 0..1Reference(PhdDevice)(Measurement) Device
.... reference 1..1stringLiteral reference, Relative, internal or absolute URL
... referenceRange
.... appliesTo 0..*CodeableConceptReference range population
Binding: https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS (required): https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS

..... coding
...... system 1..1uriIdentity of the terminology system
...... code 1..1codeSymbol in syntax defined by the system
... component 2..*BackboneElementUsed when reporting systolic and diastolic blood pressure.
.... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C0..*FrObservationBpMeasurements and simple assertions
... id Σ0..1idLogical id of this artifact
... meta Σ1..1MetaMetadata about the resource
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... versionId Σ0..1idVersion specific identifier
.... lastUpdated Σ0..1instantWhen the resource version last changed
.... source Σ0..1uriUri identifiant les systèmes tiers ayant envoyé la ressource.
.... Slices for profile Σ1..*canonical(StructureDefinition)Profiles this resource claims to conform to
Slice: Unordered, Open by value:$this
..... profile:MesFrObservationBp SΣ1..1canonical(StructureDefinition)Profiles this resource claims to conform to

Required Pattern: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-fr-observation-bp
.... security Σ0..*CodingSecurity Labels applied to this resource
Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System.


.... tag Σ0..*CodingTags applied to this resource
Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones".


... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguagesMax Binding
... text 0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... Slices for extension 0..*ExtensionExtension
Slice: Unordered, Open by value:url
... supportingInfo 0..1Reference(Resource)Other information that may be relevant to this event.
URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo
... MesReasonForMeasurement 0..1stringMotif de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-reason-for-measurement
... MesMomentOfMeasurement 0..1CodeableConceptMoment de la mesure
URL: https://interop.esante.gouv.fr/ig/fhir/mesures/StructureDefinition/mesures-moment-of-measurement
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... identifier Σ0..*IdentifierBusiness Identifier for observation
... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
... status ?!Σ1..1coderegistered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.

... Slices for category 1..*CodeableConceptClassification of type of observation
Slice: Unordered, Open by value:coding.code, value:coding.system
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


.... category:VSCat 1..1CodeableConceptClassification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... coding Σ1..*CodingCode defined by a terminology system
...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ1..1uriIdentity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... version Σ0..1stringVersion of the system - if relevant
...... code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: vital-signs
...... display Σ0..1stringRepresentation defined by the system
Required Pattern: Signes vitaux
...... userSelected Σ0..1booleanIf this coding was chosen directly by the user
..... text Σ0..1stringPlain text representation of the concept
... code Σ1..1CodeableConceptBlood pressure code
Binding: VitalSigns (extensible)
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... Slices for coding Σ0..*CodingCode defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:BPCode Σ1..1CodingCode defined by a terminology system
...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
...... version Σ0..1stringVersion of the system - if relevant
...... code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: 85354-9
...... display Σ0..1stringRepresentation defined by the system
...... userSelected Σ0..1booleanIf this coding was chosen directly by the user
.... text Σ0..1stringPlain text representation of the concept
... subject Σ0..1Reference(FrPatient)Who and/or what the observation is about
... focus ΣTU0..*Reference(Resource)What the observation is about, when it is not about the subject of record
... encounter Σ0..1Reference(FrEncounter)Healthcare event during which this observation is made
... effective[x] Σ1..1dateTimeOften just a dateTime for Vital Signs
... issued Σ0..1instantDate/Time this version was made available
... performer Σ0..*Reference(CareTeam | FrPatient | FrPractitioner | FrPractitionerRoleExercice | FrOrganization | FrRelatedPerson)Who is responsible for the observation
... dataAbsentReason C0..1CodeableConceptWhy the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..*CodeableConceptNon renseigné
Binding: http://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation (extensible)
... note 0..*AnnotationComments about the observation
... bodySite 0..1CodeableConceptObserved body part
Binding: https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS

.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... coding Σ0..*CodingCode defined by a terminology system
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... system Σ1..1uriIdentity of the terminology system
..... version Σ0..1stringVersion of the system - if relevant
..... code Σ1..1codeSymbol in syntax defined by the system
..... display Σ0..1stringRepresentation defined by the system
..... userSelected Σ0..1booleanIf this coding was chosen directly by the user
.... text Σ0..1stringPlain text representation of the concept
... method 0..1CodeableConceptHow it was done
Binding: https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS (required): https://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS

.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... coding Σ0..*CodingCode defined by a terminology system
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... system Σ1..1uriIdentity of the terminology system
..... version Σ0..1stringVersion of the system - if relevant
..... code Σ1..1codeSymbol in syntax defined by the system
..... display Σ0..1stringRepresentation defined by the system
..... userSelected Σ0..1booleanIf this coding was chosen directly by the user
.... text Σ0..1stringPlain text representation of the concept
... specimen 0..1Reference(Specimen)Specimen used for this observation
... device 0..1Reference(PhdDevice)(Measurement) Device
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... reference ΣC1..1stringLiteral reference, Relative, internal or absolute URL
.... type Σ0..1uriType the reference refers to (e.g. "Patient")
Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model).

.... identifier Σ0..1IdentifierLogical reference, when literal reference is not known
.... display Σ0..1stringText alternative for the resource
... referenceRange C0..*BackboneElementProvides guide for interpretation
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... low C0..1SimpleQuantityLow Range, if relevant
.... high C0..1SimpleQuantityHigh Range, if relevant
.... type 0..1CodeableConceptReference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..*CodeableConceptReference range population
Binding: https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS (required): https://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS


..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... coding Σ0..*CodingCode defined by a terminology system
...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ1..1uriIdentity of the terminology system
...... version Σ0..1stringVersion of the system - if relevant
...... code Σ1..1codeSymbol in syntax defined by the system
...... display Σ0..1stringRepresentation defined by the system
...... userSelected Σ0..1booleanIf this coding was chosen directly by the user
..... text Σ0..1stringPlain text representation of the concept
.... age 0..1RangeApplicable age range, if relevant
.... text 0..1stringText based reference range in an observation
... hasMember Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Related resource that belongs to the Observation group
... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)Related measurements the observation is made from
... Slices for component Σ2..*BackboneElementUsed when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
.... component:All Slices Content/Rules for all slices
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... code Σ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

..... value[x] Σ0..1Actual component result
...... valueQuantityQuantity
...... valueCodeableConceptCodeableConcept
...... valueStringstring
...... valueBooleanboolean
...... valueIntegerinteger
...... valueRangeRange
...... valueRatioRatio
...... valueSampledDataSampledData
...... valueTimetime
...... valueDateTimedateTime
...... valuePeriodPeriod
..... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
.... component:SystolicBP SΣ1..1BackboneElementUsed when reporting systolic blood pressure.
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... code SΣ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ0..*CodingSystolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:SBPCode Σ1..1CodingCode defined by a terminology system
........ id 0..1stringUnique id for inter-element referencing
........ extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
........ version Σ0..1stringVersion of the system - if relevant
........ code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: 8480-6
........ display Σ0..1stringRepresentation defined by the system
........ userSelected Σ0..1booleanIf this coding was chosen directly by the user
...... text Σ0..1stringPlain text representation of the concept
..... Slices for value[x] SΣ0..1Vital Sign Value recorded with UCUM
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantityQuantity
...... valueCodeableConceptCodeableConcept
...... valueStringstring
...... valueBooleanboolean
...... valueIntegerinteger
...... valueRangeRange
...... valueRatioRatio
...... valueSampledDataSampledData
...... valueTimetime
...... valueDateTimedateTime
...... valuePeriodPeriod
...... value[x]:valueQuantity Σ0..1QuantityActual component result
....... id 0..1stringUnique id for inter-element referencing
....... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
....... value SΣ1..1decimalNumerical value (with implicit precision)
....... comparator ?!Σ0..1code< | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit SΣ1..1stringUnit representation
Fixed Value: mm[Hg]
....... system ΣC1..1uriSystem that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code Σ1..1codeCoded form of the unit
Fixed Value: mm[Hg]
..... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: http://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation (extensible)
..... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
.... component:DiastolicBP SΣ1..1BackboneElementUsed when reporting diastolic blood pressure.
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... code SΣ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ0..*CodingCode defined by a terminology system
Slice: Unordered, Open by value:code, value:system
....... coding:DBPCode Σ1..1CodingCode defined by a terminology system
........ id 0..1stringUnique id for inter-element referencing
........ extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
........ version Σ0..1stringVersion of the system - if relevant
........ code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: 8462-4
........ display Σ0..1stringRepresentation defined by the system
........ userSelected Σ0..1booleanIf this coding was chosen directly by the user
...... text Σ0..1stringPlain text representation of the concept
..... Slices for value[x] SΣ0..1Vital Sign Value recorded with UCUM.
Slice: Unordered, Open by type:$this
Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

...... valueQuantityQuantity
...... valueCodeableConceptCodeableConcept
...... valueStringstring
...... valueBooleanboolean
...... valueIntegerinteger
...... valueRangeRange
...... valueRatioRatio
...... valueSampledDataSampledData
...... valueTimetime
...... valueDateTimedateTime
...... valuePeriodPeriod
...... value[x]:valueQuantity Σ0..1QuantityActual component result
....... id 0..1stringUnique id for inter-element referencing
....... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
....... value Σ1..1decimalNumerical value (with implicit precision)
....... comparator ?!Σ0..1code< | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

....... unit Σ1..1stringUnit representation
Fixed Value: mm[Hg]
....... system ΣC1..1uriSystem that defines coded unit form
Fixed Value: http://unitsofmeasure.org
....... code Σ1..1codeCoded form of the unit
Fixed Value: mm[Hg]
..... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: http://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation (extensible)
..... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
.... component:MeanBP Σ0..1BackboneElementMean blood pressure
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... code SΣ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

...... id 0..1stringUnique id for inter-element referencing
...... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ0..*CodingCode defined by a terminology system
Slice: Unordered, Open by value:code, value:system
....... coding:MBPCode Σ1..1CodingCode defined by a terminology system
........ id 0..1stringUnique id for inter-element referencing
........ extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
........ version Σ0..1stringVersion of the system - if relevant
........ code Σ1..1codeMean blood pressure
Fixed Value: 8478-0
........ display Σ0..1stringRepresentation defined by the system
........ userSelected Σ0..1booleanIf this coding was chosen directly by the user
...... text Σ0..1stringPlain text representation of the concept
..... value[x] Σ0..1Actual component result
...... valueQuantityQuantity
...... valueCodeableConceptCodeableConcept
...... valueStringstring
...... valueBooleanboolean
...... valueIntegerinteger
...... valueRangeRange
...... valueRatioRatio
...... valueSampledDataSampledData
...... valueTimetime
...... valueDateTimedateTime
...... valuePeriodPeriod
..... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

..... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: http://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation (extensible)
..... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result

doco Documentation for this format

 

Other representations of profile: CSV, Excel, Schematron

Terminology Bindings

PathConformanceValueSet
Observation.meta.securityextensibleAll Security Labels
Observation.meta.tagexampleCommonTags
Observation.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
Observation.statusrequiredObservationStatus
Observation.categorypreferredObservationCategoryCodes
Observation.category:VSCatpreferredObservationCategoryCodes
Observation.codeextensibleVitalSigns
Observation.dataAbsentReasonextensibleDataAbsentReason
Observation.interpretationextensiblehttp://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation
Observation.bodySiterequiredhttps://mos.esante.gouv.fr/NOS/JDV_J149-BodySiteBP-ENS/FHIR/JDV-J149-BodySiteBP-ENS
Observation.methodrequiredhttps://mos.esante.gouv.fr/NOS/JDV_J150-MethodBP-ENS/FHIR/JDV-J150-MethodBP-ENS
Observation.device.typeextensibleResourceType
Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
Observation.referenceRange.appliesTorequiredhttps://mos.esante.gouv.fr/NOS/JDV_J148-ReferenceRangeAppliesTo-CISIS/FHIR/JDV-J148-ReferenceRangeAppliesTo-CISIS
Observation.component.codeexampleLOINCCodes (a valid code from LOINC)
Observation.component.dataAbsentReasonextensibleDataAbsentReason
Observation.component.interpretationextensibleObservationInterpretationCodes
Observation.component:SystolicBP.codeexampleLOINCCodes (a valid code from LOINC)
Observation.component:SystolicBP.value[x]requiredVitalSignsUnits
Observation.component:SystolicBP.value[x]:valueQuantity.comparatorrequiredQuantityComparator
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
Observation.component:SystolicBP.interpretationextensiblehttp://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation
Observation.component:DiastolicBP.codeexampleLOINCCodes (a valid code from LOINC)
Observation.component:DiastolicBP.value[x]requiredVitalSignsUnits
Observation.component:DiastolicBP.value[x]:valueQuantity.comparatorrequiredQuantityComparator
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
Observation.component:DiastolicBP.interpretationextensiblehttp://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation
Observation.component:MeanBP.codeexampleLOINCCodes (a valid code from LOINC)
Observation.component:MeanBP.dataAbsentReasonextensibleDataAbsentReason
Observation.component:MeanBP.interpretationextensiblehttp://www.interopsante.org/fhir/structuredefinition/observation/fr-obervation-interpretation

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-3errorObservation.referenceRangeMust have at least a low or a high or text
: low.exists() or high.exists() or text.exists()